TYPE OF SYSTEM:
HIDDEN ANCHORING |
TYPES OF COVERING
SHEETS:
- terracotta hollow tiles;
- small-size natural or recomposed stone slabs;
- ceramic tiles or synthetic laminate tiles that can be
cut on edges;
- other small size materials that can be cut on edges.
|
HIDDEN ANCHORING:
Cuts on both lower and upper edges |
|
Download
the description of "VENERE NASCOSTO" system |
|
ITEM OF THE GENERAL CONDITIONS
"VENERE" system (foldaway)
Bearing frame in extruded aluminium section, alloy 6060 T5,
including only a vertical section positioned on the runout in
line with the pitch of the sheet that is shaped to act as spacer
(wall cavity of 80 ÷ 130 mm) to fix anchoring and bearing
brackets of outer covering without drilling and avoiding to
affect its protection (oxidization and electrocolour) for a
longer life.
A suitable space for ventilation to be protected with mosquito
net must be ensured.
Anchoring brackets will be made in 6060 T5 aluminium alloy,
include slots for adjustments and must be compatible with the
bearing frame and fixed by means of AISI 304 stainless steel
bolts without drilling the surface. |
| |
AISI 304 stainless steel bolts must have a suitable section
including bolt, nut, and large washer and Grover washer.
The external covering bearing systems are made in AISI 304 stainless
steel and equipped with springs and hooks release fixed into
the bearing frame and inserted into the suitable cut (kerf)
that was prearranged in the covering sheet and must be able
to contrast wind and enable the thermal expansion of the section.
The insulating panel bearing springs are made in hardened and
tempered steel and must be compatible with the bearing structure
and shaped so to be release fixed without drilling the frame.
Straight brackets must be mechanical or chemical and in stainless
steel. The type of small block (diameter, length, type) must
be established after tearing tests made on the wall or on the
materials that must be covered. The materials used, as extruded
aluminium, wall brackets, stainless steel hooks and springs
to support the insulating panel must be produced by companies
certified ISO 9002. |
Click on the images to zoom in
SYSTEM COMPONENTS: "Venere
Nascosto" system consists of the following elements:
- "CV1"extruded section in EN 6060 T5 aluminium
alloy (or similar upon need);
- "V3" and "V4" hooks to support
sheets in EN 1.4310 (AISI 301) stainless steel;
- fixing springs of the hooks with "CV1" type
"V2" section in EN 1.4310 (AISI 301 treated
stainless steel;
- "A12" and "B12" standard bearing
brackets made in EN 6060 extruded aluminium;
- fixing screws of "CV1" section to the brackets,
stainless steel straight bracket of Class A2;
- straight bracket to anchor small blocks to the wall
support must be of mechanical or chemical resin type upon
needs;
- neoprene band seal to combine sheets in respect of
hooks and section of different thicknesses depending on
needs;
- "Lana" hardened and tempered stainless steel
springs for the support of the insulation SHEETS applied
to the walls, if needed.
|
| |
DESCRIPTION OF THE SYSTEM:
The system includes the assemblage of the "CV1"
aluminium vertical section with a pitch depending on the width
of the covering sheet in addition to the design runout. “CV1”
vertical section is shaped to house without drilling the following
accessories:
- wall fixing brackets screwed with stainless steel bolts
with pitch as in the design
- "V3" and "V4" hooks for the sheet
support and the related "V2" fixing springs
to be applied by means of the suitable tool into the vertical
rod groove, with pitch depending on the height of the
covering sheet in addition to the design runout;
- the bearing springs of the insulating panel are release
applied, if necessary;
The lack of drilling enables to not affect the superficial
protection (oxidization or electrocolour) and to improve
the life of sections.
The main characteristic of this version of “Venere”
system is that sheets must be equipped with continuous cutting
on both upper and lower edges that enables to house bearing
and retaining hooks of sheets. These hooks are invisible
on the front side.
The sheet is integrated with the frame by means of interposition
of a neoprene seal with suitable thickness and the application
of silicone points, where necessary.
Once laid, each sheet can be independently assembled and/or
disassembled in respect of all the others.
The frame, which enables each type of adjustment, can contrast
wind action and enables the thermal expansion of the different
components. |
| |
VOLUMES:
- The standard structure is 110 mm plus the thickness
of the covering sheets with a standard adjustment of ±
25 mm.
- The standard structure is 110 mm plus the thickness
of the covering sheets with a standard adjustment of ±
25 mm.
The diagram of the standard system is shown in the Document
Attached. |
| |
| NOTE: THE EFFECTIVE COMPONENTS CAN BE ADJUSTED
DURING THE DESIGN PHASE. |
| |
|
| |
|
| |
|
|
|
 |